| Availability: | |
|---|---|
| Quantity: | |
BWS-150KT-CP
Brightway Solar

Model BWS - 150KT - CP is a highly advanced and powerful product. In the DC domain, it features a voltage range of 420V to 850V and a maximum current of 405A. When it comes to AC on-grid operation, the maximum output power is an impressive 165kVA, and the rated output power is 150KW. Boasting a maximum efficiency of 97.10%, this model is not only energy-efficient but also highly reliable. With dimensions of 800×800×2050mm and a weight of 1057kg, it offers a compact and manageable design. Additionally, it comes with various protective features and can operate effectively in a wide range of temperatures, humidity levels, and altitudes, making it a top choice for diverse industrial and commercial uses.
Technical Specifications
| Model | BWS-150KT-CP |
| DC(battery) | |
| Voltage range (V) | 420V-850V |
| Max. Current (A) | 405A |
| AC(on-grid) | |
| Max output power(kVA) | 165kVA |
| Rate output power(kW) | 150KW |
| Rated voltage(V) | 400V |
| Voltage range(V) | 320V-460V |
| Rated current(A) | 216A |
| Max. output current(A) | 238A |
| Rated frequency (Hz) | 50/60Hz |
| Frequency range (Hz) | 45-55/55-65Hz |
| THDI | <3% |
| Power factor | 1lagging-1leading(Settable) |
| AC connection | 3W+N+PE |
| AC(off grid) | |
| Rated voltage(V) | 400V |
| THDU | <1% Linear <5% Nonlinear |
| Rated frequency(Hz) | 50/60Hz |
| Overload capacity | 110% long-term |
| General data | |
| Max.efficiency | 97.10% |
| Ingress protection | IP21 |
| Noise emission(dB) | <70dB |
| Operating temperature | -30~+55℃ |
| Cooling | Forced air |
| Relative humidity | 0 ~95% non-condensing |
| Altitude | 5,000m(>3,000 Derating) |
| Dimension W*D*H (mm) | 800×800×2050mm |
| Weight(kg) | 1057kg |
| Transformer ratio | 270/400 |
| Self-consumption (W) | <10W |
| On/ Off grid switching | Automatic |
| Display and communication | |
| Display | LCD touch-screen |
| BMS communication | RS485/CAN |
| EMS communication | RS485,TCP/IP |
| Certificates | IEC/EN62109-1/-2, IEC/EN 62477-1, IEC/EN 61000-6-2, IEC/EN 61000-6-4,CGC |

Model BWS - 150KT - CP is a highly advanced and powerful product. In the DC domain, it features a voltage range of 420V to 850V and a maximum current of 405A. When it comes to AC on-grid operation, the maximum output power is an impressive 165kVA, and the rated output power is 150KW. Boasting a maximum efficiency of 97.10%, this model is not only energy-efficient but also highly reliable. With dimensions of 800×800×2050mm and a weight of 1057kg, it offers a compact and manageable design. Additionally, it comes with various protective features and can operate effectively in a wide range of temperatures, humidity levels, and altitudes, making it a top choice for diverse industrial and commercial uses.
Technical Specifications
| Model | BWS-150KT-CP |
| DC(battery) | |
| Voltage range (V) | 420V-850V |
| Max. Current (A) | 405A |
| AC(on-grid) | |
| Max output power(kVA) | 165kVA |
| Rate output power(kW) | 150KW |
| Rated voltage(V) | 400V |
| Voltage range(V) | 320V-460V |
| Rated current(A) | 216A |
| Max. output current(A) | 238A |
| Rated frequency (Hz) | 50/60Hz |
| Frequency range (Hz) | 45-55/55-65Hz |
| THDI | <3% |
| Power factor | 1lagging-1leading(Settable) |
| AC connection | 3W+N+PE |
| AC(off grid) | |
| Rated voltage(V) | 400V |
| THDU | <1% Linear <5% Nonlinear |
| Rated frequency(Hz) | 50/60Hz |
| Overload capacity | 110% long-term |
| General data | |
| Max.efficiency | 97.10% |
| Ingress protection | IP21 |
| Noise emission(dB) | <70dB |
| Operating temperature | -30~+55℃ |
| Cooling | Forced air |
| Relative humidity | 0 ~95% non-condensing |
| Altitude | 5,000m(>3,000 Derating) |
| Dimension W*D*H (mm) | 800×800×2050mm |
| Weight(kg) | 1057kg |
| Transformer ratio | 270/400 |
| Self-consumption (W) | <10W |
| On/ Off grid switching | Automatic |
| Display and communication | |
| Display | LCD touch-screen |
| BMS communication | RS485/CAN |
| EMS communication | RS485,TCP/IP |
| Certificates | IEC/EN62109-1/-2, IEC/EN 62477-1, IEC/EN 61000-6-2, IEC/EN 61000-6-4,CGC |